Setting Up Global Connectivity Between MxEasy And Door Station
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
www.mobotix.com • [email protected]
3. Activate the checkbox Use secure connections (SSL) in the Access data tab.
4. Click Apply or OK to complete the changes on the camera.
5. Reboot your camera when you are prompted to do so.
The camera can now only be reached via an SSL-encrypted connection. You can also use
the encrypted connection from a Web browser by entering the camera's address, as in
the following example:
https://Fritz-Mueller.dyndns.org:19801
Now proceed as described above in Section 4.1.3 from Step 3 onwards. You have now
integrated a T24 into MxEasy via the Internet.
Please note: For a computer with MxEasy that is remotely connected to the T24 via the
Internet, any ringing on the door will only be signaled acoustically and optically if the
computer (and the T24) are registered with a DynDNS service with the host name and the
port of its Internet router in MxEasy as the remote station. If this function (doorbell mes
-
sage) is also required while you are out for unknown ports (e.g., in the WLAN network of
a hotel or hotspot), we recommend using the MOBOTIX App for iPhone, iPad and iPod
touch, which has been developed specially for mobile use.
Notes
The IP addresses given here for cameras, routers, the ports and the DynDNS name
'Fritz-Mueller.dyndns.org' are only intended as examples. They should not be used
under any circumstances in order to protect your system from tampering. Specify
your own names and ports.
Access to the password-protected T24 website e.g., if you want to view live images or
open the door, is also possible in the browser of mobile Internet devices. The remote-
controlled door opening function is extremely practical if, for example, your T24 is not
equipped with an RFID or PIN-controlled access module (T24 KeypadRFID), but you do
not have the door key with you at the moment.
Make sure that you have changed the default Access data for the Door Station (user
name 'admin' and password 'meinsm') when using the system for the first time: User
name remains admin, new secure password becomes the supervisor PIN for your
system (also see the Note at the beginning of Section 4).