A special system restore procedure is required after exchanging modules. It is described
in 5.2.1– 5.2.6 below.
5.2.1 Exchanging Keypad– With System Restore
You need to disconnect the door station’s power supply
before exchanging the keypad. To restore the system after
exchanging it, you will need an up-to-date backup of the
system configuration.
Proceed As Follows:
1. Disconnect the door station from the power supply (for
example, remove the network plug).
2. Remove the keypad to be exchanged from the module frame as described in the
T24 System Manual Part 1/Section 2.4.6 (Removing And Exchanging Modules).
3.
Exchange the keypads. Take care not to damage the cabling or mix up the connections.
The connection diagrams are provided in the T24 System Manual Part 1.
4. Reconnect the power supply, wait until the system has booted and run a system
restore via the video phone, as described in 5.2. The door station is now ready
for operation and can once again be used with the PINs and transponder cards
set up for your system.
5.2.2 Exchanging Security Door Opener– With System Restore
You need to disconnect the door station’s power supply before
exchanging the security door opener. To restore the system
after exchanging it, you will need an up-to-date backup of
the system configuration.
Proceed As Follows:
1.
Disconnect the door station from the power supply (for example, remove the network
plug).
2. Exchange the security door openers. Take care not to damage the cabling or mix
up the connections. The connection diagrams are provided in the T24 System
Manual Part 1.
3. Reconnect the power supply, wait until the system has booted and run a system
restore via the video phone, as described in 5.1. The door station is now ready
for operation and can once again be used with the PINs and transponder cards
set up for your system.
Contact your MOBOTIX
Support team to
exchange (used) keypads
and security door
openers that no longer
have factory default
condition (the devices
will need to undergo
a hardware reset)